Page 4 - UVP05 Premium System EN
P. 4

Premium system
Features
Stainless steel housing IP67
Premium UV lamp 12,000 operating hours
Quartz glass pane with breakage detector
Cups:
Approximately 4 seconds* of exposure, depending on height of cup
It is sufficient to illuminate e.g. two cycles
Films:
Films require 1 to 2 seconds* of exposure
Boards are preliminarily disinfected and also exposed for only 1 to 2 seconds*
Allow at least 20mm between the UV module
and the film
The appropriate Premium system variant also depends
on the dispensing/feeding length as well as on the microorganism to be killed. Bacteria, for example, require a lower lethal UV dose than mold. Please ask our
UV application experts for assistance with adapting the variant to your filling line.
Testing on site – ask for our systems for rent to test the direct application of the Premium system in your process.
Compact – the modules require very little space Electronic ballasts and the ventilator share the same control module for ease of retrofitting
Air, not water-cooled; the ventilator in the control module sufficiently cools up to three UV modules Equipped with a service hour meter and an On/Off indicator
Supply voltage 180–264V /50/60Hz connectors Package includes: UV module and control module with power supply, service hour meter, forced ventilation/air cooling and air hoses
Premium systems are available with UV modules in 5 standard sizes
How to choose the correct Premium system variant
Cups, heat sealing films or sealing boards require different exposure times:
*No guarantee / all data reflects test results obtained under laboratory conditions.
Premium system with 2 UV lamps and control module
4