Page 5 - UVP05 Premium System EN
P. 5

Premium systems for UV disinfection
Technical data
Fig. 1 Fig. 2
Technical data of Premium systems with 2 lamps
UV module type
Radiation exit area (size of window) Size of UV module
Irradiance in 20 mm distance Installed power (Power input)
Unit P2036
mm 367 × 111
mm 560×170×110 mW/cm2 65
watt 430
P2062
617 × 111 780×170×110 65
550
P2087
867 × 111 1060×170×110 65
740
P2132
1315 × 111 1508×170×160 65
1800
In all 2-lamp UV modules, ventilation hoses can be installed either at the wide rear side of the UV modules (Fig. 1) or at the top at the narrow side (Fig. 2). On the UV modules marked with an "S", the connections are located at the long, narrow side.
Technical data of Premium systems with 6 lamps
UV module type
Radiation exit area (size of window) Size of UV module
Irradiance in 20 mm distance Installed power (Power input)
Unit P6036.30
mm 367 × 298
mm 550×360×155 mW/cm2 90
watt 900
P6062.30
615 × 298 780×360×155 90
1400
P8087.38
865 × 372 1030×434×155 103
2700
Technical data of Premium systems with 8 lamps
UV module type
Radiation exit area (size of window) Size of UV module
Irradiance in 20 mm distance Installed power (Power input)
Unit P8062.38
mm 615 × 372
mm 780×434×155 mW/cm2 103
watt 2500
UV modules with 2, 6 or 8 lamps can be operated with one control module.
5


































































































   2   3   4   5   6