Page 6 - Xenon Flash Lamp Modules EN
P. 6

Technical Data & Module Selection Guide
Technical data
Input Parameter
Input voltage (DC)
Input current (actual value) Input current (average) Trigger input
Trigger input impedance Emission frequency
11 V – 28 V
5 V ± 10 %, about 10 mA
390 Ω
Max. 530 Hz
1.5 mm
UV glass
185 – 2000 nm
< 2.0 % *
1 × 109 flashes
5W**
28 V : 0.72 A
28 V : 0.46 A Pulse width: min. 10 μsec.
11 V : 1.40 A
12V : 1.05A
24V:0.77A
11V : 1.00A
12V : 0.92A
24V : 0.49A
Output Parameter
Arc size
Window material
Spectral output range
Light output stability
Typical lifetime
Max. average input
Discharge capacitor
Main discharge voltage
General Parameter
Cooling method
Operating ambient temperature
Storage temperature
RoHS Directive Comliance
Vibration resistance (when non-operating)
Shock resistance (when non-operating)
Weight
0.047μF / 0.11μF / 0.22μF / 0.28μF ***
400–600V****
Cooling is needed when the enclosure temperature goes up to 50 °C or more
0 – 40 °C humidity below 95 % RH
-40 – 90°C humidity below 95% RH
Applicable
10 – 55 Hz, 19.6 m/s2 directions 1 hour per direction
Max. 196.1 m/s2 3 directions One time per direction
250g
6
* Stability of light output is calculated as followes: stability of light output = 100 × (output standard deviation / average light output)
** Max. flash energy × emission frequency
*** One of those capacitors to be installed upon request **** Adjustable with variable trimmer or external control
voltage from 3.2V to 4.8V